{"product_id":"clemco-druckprufmanometer-hng-komplettset","title":"HNG nozzle pressure test gauge, Complete Set","description":"\u003ch5\u003eClemco HNG nozzle pressure test gauge – Test nozzle pressure directly under actual blasting load\u003c\/h5\u003e\u003cp\u003eThe Clemco HNG nozzle pressure test gauge is a diagnostic tool for sandblasting systems. It allows you to measure the actual blasting pressure available at the nozzle during operation. This value accounts for losses due to air preparation, fittings, couplings, and the blast hose.\u003c\/p\u003e\u003cdiv style=\"background:#f5f5f5;padding:16px;border-radius:10px;margin:16px 0;\"\u003e\n\u003cstrong\u003eYour Benefits\u003c\/strong\u003e\u003cbr\u003e✅ Measurement near the blast nozzle\u003cbr\u003e✅ Diagnosis of pressure losses under load\u003cbr\u003e✅ Helps with compressor and hose selection\u003cbr\u003e✅ Supports reproducible blasting results\u003cbr\u003e✅ Complete kit for maintenance and service\u003c\/div\u003e\u003chr\u003e\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\u003cdiv style=\"overflow-x:auto;margin:16px 0;border:1px solid #d9dee3;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;border-collapse:separate;border-spacing:0;min-width:620px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:36%;padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#eef1f3;font-weight:700;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;\"\u003eHNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;\"\u003eNozzle Pressure Test Gauge \/ Pressure Test Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#eef1f3;font-weight:700;\"\u003eItem No.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;\"\u003e01232I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;font-weight:700;\"\u003eMeasurement task\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;\"\u003eOperating pressure in the blast hose near the nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px 12px;background:#eef1f3;font-weight:700;\"\u003eDelivery Format\u003c\/td\u003e\n\u003ctd style=\"padding:11px 12px;\"\u003eComplete Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003chr\u003e\u003ch5\u003eWhy Nozzle Pressure Is Critical\u003c\/h5\u003e\u003cp\u003eA high outlet pressure at the compressor does not automatically mean that this pressure is present at the nozzle. Pipes that are too small, long hoses, tight couplings, dirty filters, or a worn nozzle can cause significant pressure loss.\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eTypical Applications\u003c\/h5\u003e\u003cp\u003e✔ Troubleshooting low blasting performance\u003cbr\u003e✔ Comparison of different hose lengths and diameters\u003cbr\u003e✔ Inspection after maintenance or modification\u003cbr\u003e✔ Documentation of recurring system statuses\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eMeasurement and Safety\u003c\/h5\u003e\u003cp\u003eMeasurements should only be performed by trained personnel in accordance with the application guidelines. Wear protective equipment and keep hands out of the direct blast and rebound areas.\u003c\/p\u003e\u003cp\u003e💡 \u003cstrong\u003ePractical tip:\u003c\/strong\u003e Document a baseline value after successful commissioning. This makes it easier to identify and address any deviations that arise later.\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eFAQ\u003c\/h5\u003e\u003cp\u003e\u003cstrong\u003eWhy isn’t the boiler pressure gauge sufficient?\u003c\/strong\u003e\u003cbr\u003eIt does not show the pressure losses up to the nozzle.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen should measurements be taken?\u003c\/strong\u003e\u003cbr\u003eIn case of performance issues, after modifications, when using a new nozzle size, and as part of preventive maintenance.\u003c\/p\u003e","brand":"Clemco","offers":[{"title":"Default Title","offer_id":52744693809499,"sku":"01232I","price":639.0,"currency_code":"SEK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/druckpruef-manometer-hng-clemco-01232i.jpg?v=1775217222","url":"https:\/\/strahltechnik-express.de\/en-se\/products\/clemco-druckprufmanometer-hng-komplettset","provider":"ABS Strahltechnik","version":"1.0","type":"link"}