{"product_id":"rpb-safety-atemluftklimagerat-c40-nova-3-nova-2000","title":"C40 breathing-air climate control unit for Nova 3 and Nova 2000 blast helmets","description":"\u003ch4\u003eRPB Safety C40 – Breathing-air climate control unit for cooling and heating the supplied breathing air\u003c\/h4\u003e\u003cp\u003eThe rpb Safety C40 is a compact climate control unit for compressed-air-powered respiratory protection systems. It allows the user to adjust the temperature of the supplied breathing air directly from the belt, making it more comfortable to work in hot or cold conditions.\u003c\/p\u003e\u003cp\u003eA lever can be used to switch between cooling and heating modes. The C40 can cool the incoming breathing air by up to 29 °C or heat it by up to 18 °C. The airflow can also be adjusted using a separate control.\u003c\/p\u003e\u003chr\u003e\u003ch4\u003eYour Benefits at a Glance\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✅ Cooling and heating functions in a single unit\u003cbr\u003e✅ Cooling of the breathing air by up to 29 °C\u003cbr\u003e✅ Heats breathing air by up to 18 °C\u003cbr\u003e✅ Easy switching via a lever\u003cbr\u003e✅ Continuously adjustable airflow\u003cbr\u003e✅ Very lightweight at only 277 g without the belt\u003cbr\u003e✅ 360° rotatable air inlet for convenient hose routing\u003cbr\u003e✅ Rugged construction for tough industrial applications\u003cbr\u003e✅ Low maintenance requirements\u003cbr\u003e✅ Suitable for RPB Nova 3 and Nova 2000\u003c\/div\u003e\u003chr\u003e\u003ch4\u003e📦 Package Contents\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✔ rpb Safety C40 Air Conditioner\u003cbr\u003e✔ Belts\u003cbr\u003e✔ Connection type according to product configuration\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cdiv style=\"overflow-x:auto;border:1px solid #d9d9d9;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;min-width:680px;border-collapse:separate;border-spacing:0;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"position:sticky;left:0;z-index:3;background:#e5e5e5;padding:12px;border-right:1px solid #d0d0d0;border-bottom:1px solid #c8c8c8;text-align:left;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#e5e5e5;padding:12px;border-bottom:1px solid #c8c8c8;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eC40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eCooling capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eup to 29 °C below the inlet temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eHeat output\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eup to 18 °C above the inlet temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eoperating pressure\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003e55 to 80 psi \/ approx. 3.8 to 5.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eAir consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eapprox. 25 cfm \/ approx. 708 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003e277 g without belt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eApproval\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eEN 14594:2005, Class 3B\/4B in an approved combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;text-align:left;font-weight:600;\"\u003eItem Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e03-502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eHow It Works\u003c\/h4\u003e\u003cp\u003eThe C40 operates on the vortex tube principle. A portion of the supplied compressed air is used for temperature separation, while the required breathing air flow is directed to the helmet. Therefore, the compressed air supply must cover not only the air requirements of the respiratory protection system but also the additional consumption of the air conditioning unit.\u003c\/p\u003e\u003cdiv style=\"margin-top:16px;padding:14px 16px;background:#f3f3f3;border-radius:10px;\"\u003e\n\u003cstrong\u003e📌 Important:\u003c\/strong\u003e\u003cbr\u003eThe C40 may only be operated as part of a respiratory protection configuration approved by the manufacturer. A compressed air supply that is too small may fail to deliver the required airflow to the helmet.\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eMaintenance and Care\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✔ Clean the silencer regularly and replace it as needed\u003cbr\u003e✔ Keep the air intake and connections clean\u003cbr\u003e✔ Check the function of the temperature lever and air regulator\u003cbr\u003e✔ Protect the equipment from abrasive media and paint mist\u003cbr\u003e✔ Use only approved breathing-air hoses\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eFAQ – Frequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCan the C40 heat and cool at the same time?\u003c\/strong\u003e\u003cbr\u003eNo, a lever is used to switch between cooling and heating modes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow much air does the C40 require?\u003c\/strong\u003e\u003cbr\u003eApproximately 25 cfm or about 708 l\/min at 55 to 80 psi.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the C40 compatible with the Nova 3 and Nova 2000?\u003c\/strong\u003e\u003cbr\u003eYes, in the approved hose and connection configuration.\u003c\/p\u003e","brand":"rpb Safety","offers":[{"title":"Default Title","offer_id":52531746799963,"sku":"03-502","price":534.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/atemluft-klimageraet-c40-gvs-rpb-safety-03-502.jpg?v=1772896811","url":"https:\/\/strahltechnik-express.de\/en-pt\/products\/rpb-safety-atemluftklimagerat-c40-nova-3-nova-2000","provider":"ABS Strahltechnik","version":"1.0","type":"link"}