Vortex Breathing-Air Climate Control Unit for Commander 2 Blast Helmet, K10, ZGH
The North Vortex breathing-air climate control unit ensures comfortably tempered breathing air during professional blasting operations. Depending on the connection, the breathing air can be cooled or heated, thereby increasing comfort in high or low ambient temperatures. The robust, low-maintenance Vortex system is compatible with the North Commander 2, K10, and ZGH blast helmets and is suitable for daily industrial use.
Tax-free EU shipping after VAT ID verification at checkout
Free shipping within Germany on orders of €99 or more
Vortex Breathing-Air Climate Control Unit for Commander 2 Blast Helmet, K10, ZGH is in stock and will be shipped as soon as it is available again
Questions & Help
Questions & Help
Do you have questions about one of our products, or would you like expert advice on selecting the right solution for your application?
No problem—give us a call! Tel. +49 (0) 2551 5030
Send us an email! shop@strahltechnik-express.de
Use our online chat or the contact form
Leasing & Rent-to-Own
Leasing & Rent-to-Own
We offer leasing and rent-to-own financing options exclusively to business owners, tradespeople, and the self-employed for selected products with a net merchandise value of €1,000 or more. Below you will find the key differences between these two financing options.
Leasing
In a lease, the product is made available to the lessee for use in exchange for regular lease payments. The lessor is responsible for accounting for the lease. The lease payments can generally be claimed as business expenses for tax purposes. These are gross payments, and value-added tax is charged throughout the entire term. At the end of the agreed-upon basic lease term, it is generally possible to purchase the product.
Hire Purchase
Hire purchase is economically equivalent to installment purchase. The product is capitalized on the hire purchaser’s balance sheet and depreciated in accordance with the official depreciation tables. Upon payment of the final hire purchase installment, ownership of the item is transferred to the hire purchaser. Value-added tax must be paid in full with the first hire purchase installment (transitory item).
Shipping & Delivery
Shipping & Delivery
Depending on the size, weight, and nature of our goods, they are shipped either via parcel service or freight carrier. We select the shipping method at our reasonable discretion.
The delivery times listed in the online store are non-binding estimates, unless a binding delivery date has been expressly confirmed in writing. They are based on the information available from our manufacturers, suppliers, and logistics partners at the time the order is placed.
Most of the products offered are shipped directly from the manufacturer or from external central warehouses (direct shipping). As a result, delivery times may differ from the estimated times provided. Delivery delays may occur, particularly in the event of material shortages, production delays, supply bottlenecks, force majeure, or other circumstances beyond our control.
Disclaimer:
We assume no liability for delivery delays resulting from circumstances beyond our control. This applies in particular to delays caused by manufacturers, suppliers, shipping companies, or other third parties. Liability for any resulting damages—in particular for indirect damages, consequential damages, or lost profits—is excluded to the extent permitted by law.
Partial deliveries are permitted, provided they are reasonable for the customer. This does not result in additional shipping costs, unless otherwise agreed.
The exact delivery time for an item can be provided on an individual basis upon request, either before or after the order is placed.
Please contact us by phone at +49 (0)2551 5030 or by email at shipping@strahltechnik-express.de.
In the event of significant delivery delays, we will inform the customer immediately. The customer’s mandatory statutory rights remain unaffected by this.
Vortex Breathing-Air Climate Control Unit for Commander 2 Blast Helmet, K10, ZGH is in stock and will be shipped as soon as it is available again
North Vortex breathing-air climate control unit – heated or cooled breathing air for blast helmets
The North Vortex breathing-air climate control unit is a personal climate control unit for compressed-air-powered blast helmets and respiratory protection systems. Depending on the connection side, it can heat or cool the supplied breathing air, thereby significantly improving comfort in cold or hot working conditions.
The device operates purely mechanically based on the Vortex principle and has no moving internal parts. This makes it robust, low-maintenance, and suitable for daily use in blasting rooms, workshops, on construction sites, and in industrial surface treatment.
Your Benefits at a Glance
✅ Portable air conditioning unit for breathing air systems
✅ Heating and cooling functions in a single unit
✅ Change in the temperature of the exhaled air by up to approximately 20 °C
✅ Purely mechanical function with no moving internal parts
✅ Air flow adjustable via integrated regulator
✅ Suitable for North Commander 2, K10, and ZGH
✅ Sturdy aluminum housing
✅ Lightweight at approx. 400 g
✅ Suitable for professional blasting and painting work
✅ Can be worn directly on the belt
Technical Specifications
| Product Type | Breathing-Air Climate Control Unit / Vortex Regulator |
| Function | Heating or cooling the supplied breathing air |
| Temperature Change | Up to approx. 20 °C, depending on operating pressure, air flow, and ambient conditions |
| Working pressure | At least 4.5 bar, at most 7 bar |
| Recommended Operating Range | Approx. 4.5 to 6.5 bar |
| Compressed Air Consumption | Approx. 350 Nl/min at 5 bar |
| Minimum air supply to the helmet | Approx. 165 l/min at 4.5 bar and a hose length of 40 m |
| Ambient temperature | Approx. −10 to +60 °C |
| Maximum hose length | 40 m |
| Noise level | Approx. 91 dB(A) at 5.5 bar and maximum airflow |
| Material | Aluminum |
| Weight | Approx. 400 g |
| Item Number | A150275 |
Compatibility
✔ North Commander 2
✔ North K10
✔ North ZGH
✔ Additional compatible North respiratory protection systems with matching connectors
Note: Actual compatibility must be verified based on the helmet, connector, breathing-air hose, and existing system configuration.
How It Works
The Vortex air conditioner splits the incoming compressed air into a warm and a cold air stream. Heated air is supplied through the red outlet, and cooled air through the blue outlet. Depending on the desired function, the corresponding outlet is connected to the breathing air connection on the blast helmet.
The air flow can be adjusted using the built-in regulator. The desired temperature effect is achieved after a short operating time. For optimal performance, the compressed air supply must be sufficiently sized and free of moisture, oil, and harmful contaminants.
Scope of Delivery
✔ North Vortex breathing-air climate control unit
✔ Belt clip or mount
✔ Integrated air flow regulator
✔ Connections for heating and cooling operation
Note: Blast helmets, breathing-air hoses, breathing-air filters, compressors, and other accessories are not included in the scope of delivery unless they are expressly mentioned in the offer.
Typical Applications
✔ Sandblasting and compressed air blasting
✔ Blasting halls and blasting rooms
✔ Corrosion protection
✔ Painting and coating work
✔ Shipyards and Shipbuilding
✔ Steel and Bridge Construction
✔ Industrial and maintenance work
✔ Hot or cold work environments
Safety and Compressed-Air Quality
The Vortex air conditioning unit must be operated exclusively with suitable breathing air. Oxygen or oxygen-enriched air must not be used. The compressed air must meet the requirements of the applicable breathing air standards and be sufficiently dried.
At temperatures below freezing, moisture in the compressed air can cause icing and interrupt the air flow. The compressed-air treatment system must therefore be adequately sized. If the breathing-air supply is interrupted or insufficient, the hazardous area must be evacuated immediately.
The device does not reduce ambient noise. Due to the specified noise level, appropriate hearing protection is required.
FAQ – Frequently Asked Questions
Can the Vortex unit heat and cool?
Yes. Depending on the outlet used, the breathing air is heated or cooled.
How much does the temperature change?
Depending on operating conditions, a temperature change of up to approximately 20 °C is possible.
What is the compressed air consumption?
Compressed-air consumer: consumption is approximately 350 Nl/min at 5 bar.
What operating pressure is required?
The permissible range is approximately between 4.5 and 7 bar. For many applications, a range of about 4.5 to 6.5 bar is used.
Is this device compatible with the Commander 2?
Yes. The Vortex air conditioner is designed for use with the Commander 2, as well as the K10 and ZGH, among others.
Is a breathing-air filter included?
No. A suitable breathing-air filter and a safe source of breathing air must be provided separately.