{"title":"blast cabinet extraction systems","description":"\u003ch5\u003eBlast cabinets: Extraction systems and filter systems for clear visibility during blasting\u003c\/h5\u003e\u003cp\u003eSuitable \u003cstrong\u003eblast cabinet extraction systems\u003c\/strong\u003e remove dust-laden air from the work area to the filtration unit, thereby ensuring a clear view of the workpiece. Blasting produces fine abrasive particles, dust, and removed surface particles that would remain in the blast cabinet without adequate extraction.\u003c\/p\u003e\u003cp\u003eIn this category, you will find extraction and dust collection systems specifically designed for blast cabinets, featuring various airflow rates and filter cleaning methods. The current product line includes solutions with both manual and automatic filter cleaning.\u003c\/p\u003e\u003cp\u003eWhen selecting equipment, the booth volume, openings, abrasive media used, dust volume, and required air flow rate must all be compatible. Even a high-performance extraction system cannot replace regular inspection and maintenance of the filters.\u003c\/p\u003e\u003cdiv style=\"background:#f5f5f5;border-radius:10px;padding:18px;margin:22px 0;\"\u003e\n\u003ch5\u003eChoosing the Right Blast Cabinet Extraction System\u003c\/h5\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Size the air flow capacity to match the booth size\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Take into account the amount of dust and the abrasive media used\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Choose between manual or automatic filter cleaning based on operating time\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Check the connection cross-section and duct routing\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Check the filter condition regularly\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003e✅ Evaluate extraction performance during actual blasting operations\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"contracor-staubabscheider-dc-fur-sandstrahlkabine-3-grossen","title":"DC Dust Collector for Blast Cabinets, with Automatic Filter Cleaning, 3 Sizes","description":"\u003ch5\u003eContracor DC Dust Collector for Blast Cabinets with Automatic Filter Cleaning\u003c\/h5\u003e\n\u003cp\u003eThe Contracor DC Series dust collectors were developed specifically for use in professional blast cabinets. They reliably remove the dust generated during blasting from the air inside the cabinet, ensuring a clear view of the workpiece and a clean working environment.\u003c\/p\u003e\n\u003cp\u003eThe compact extraction systems feature an integrated fan and high-performance cartridge filters. The DC-550 and DC-750 models are equipped with automatic pulse-jet filter cleaning. The DC-370 can be retrofitted with automatic filter cleaning as an option.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eYour Benefits at a Glance\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e✅ Effective dust collector for professional blast cabinets\u003c\/li\u003e\n\u003cli\u003e✅ Significantly improved visibility during the blasting process\u003c\/li\u003e\n\u003cli\u003e✅ A cleaner and more pleasant work environment\u003c\/li\u003e\n\u003cli\u003e✅ Large filter surfaces for extended operating times\u003c\/li\u003e\n\u003cli\u003e✅ Automatic filter cleaning on the DC-550 and DC-750\u003c\/li\u003e\n\u003cli\u003e✅ Compact design with integrated fan\u003c\/li\u003e\n\u003cli\u003e✅ Suitable for Contracor ECO and CAB blasting cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\n\u003cdiv style=\"overflow-x: auto; border: 1px solid #d9d9d9; border-radius: 10px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 800px; border-collapse: separate; border-spacing: 0; text-align: center;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"padding: 12px; background: #e5e5e5;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"padding: 12px; background: #e5e5e5;\"\u003eDC-370\u003c\/th\u003e\n\u003cth style=\"padding: 12px; background: #e5e5e5;\"\u003eDC-550\u003c\/th\u003e\n\u003cth style=\"padding: 12px; background: #e5e5e5;\"\u003eDC-750\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eflow rate\u003c\/td\u003e\n\u003ctd\u003e800 m³\/h\u003c\/td\u003e\n\u003ctd\u003e870 m³\/h\u003c\/td\u003e\n\u003ctd\u003e900 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eNegative pressure\u003c\/td\u003e\n\u003ctd\u003e1075 Pa\u003c\/td\u003e\n\u003ctd\u003e1310 Pa\u003c\/td\u003e\n\u003ctd\u003e1470 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eFilter area\u003c\/td\u003e\n\u003ctd\u003e2.7 m²\u003c\/td\u003e\n\u003ctd\u003e7.5 m²\u003c\/td\u003e\n\u003ctd\u003e11.0 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eEngine power\u003c\/td\u003e\n\u003ctd\u003e0.37 kW\u003c\/td\u003e\n\u003ctd\u003e0.55 kW\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eDimensions (D × W × H)\u003c\/td\u003e\n\u003ctd\u003e600 × 600 × 1620 mm\u003c\/td\u003e\n\u003ctd\u003e650 × 600 × 2010 mm\u003c\/td\u003e\n\u003ctd\u003e730 × 680 × 2060 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e60 kg\u003c\/td\u003e\n\u003ctd\u003e100 kg\u003c\/td\u003e\n\u003ctd\u003e122 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch5\u003eDimensions\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/abmessungen-filteranlage-dc-370-dc-550-dc-750-contracor.jpg?v=1785871117\" alt=\"\"\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003chr\u003e\n\u003ch5\u003eVariants and Item Numbers\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e✔ DC-370 – Item Number 10117512A\u003c\/li\u003e\n\u003cli\u003e✔ DC-550 – Item Number 10117513\u003c\/li\u003e\n\u003cli\u003e✔ DC-750 – Item Number 10117514\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch5\u003eHow It Works and Applications\u003c\/h5\u003e\n\u003cp\u003eDuring the blasting process, the extraction system generates a controlled airflow through the blasting booth. Dust particles are captured by the filter cartridges, while the cleaned air is released back into the environment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Blast cabinets in workshops\u003c\/li\u003e\n\u003cli\u003e✔ Industrial Blasting\u003c\/li\u003e\n\u003cli\u003e✔ Retrofitting existing extraction systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch5\u003eMaintenance and Safety\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Check filters regularly and clean them as needed\u003c\/li\u003e\n\u003cli\u003e✔ Check extraction lines for leaks\u003c\/li\u003e\n\u003cli\u003e✔ Perform maintenance work only when the system is shut down\u003c\/li\u003e\n\u003cli\u003e✔ Replace the filter according to operating conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch5\u003eFAQ – Frequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhich DC dust collector is the right one?\u003c\/strong\u003e\u003cbr\u003eThe selection depends on the size of the blast cabinet, the amount of dust generated, and the desired extraction capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich models feature automatic filter cleaning?\u003c\/strong\u003e\u003cbr\u003eThe DC-550 and DC-750 models come standard with pulse-jet filter cleaning. The DC-370 can be upgraded with this feature as an option.\u003c\/p\u003e","brand":"Contracor","offers":[{"title":"DC-370","offer_id":49048538710363,"sku":"10117512A","price":1701.82,"currency_code":"EUR","in_stock":true},{"title":"DC-550","offer_id":49048538743131,"sku":"10117513","price":2004.91,"currency_code":"EUR","in_stock":true},{"title":"DC-750","offer_id":49048538775899,"sku":"10117514","price":2369.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/absaugung-staubabscheider-sandstrahlkabine-dc-contracor.jpg?v=1726763132"},{"product_id":"radler-ruf-sandstrahlkabinenabsaugung-ae-t-0-3-600-m3-h","title":"Radler \u0026 Ruf Blast Cabinet Dust Collector AE-T 0,3, 600 m³\/h, 0.37 kW, with Manual Filter Cleaning","description":"\u003ch5\u003eRadler \u0026amp; Ruf AE-T 0,3 Blast Cabinet Dust Collector – Compact Dust Collector with Manual Filter Cleaning\u003c\/h5\u003e\n\u003cp\u003eThe \u003cstrong\u003eAE-T 0,3 blast cabinet dust collector\u003c\/strong\u003e is a compact dust collection system for blast cabinets. With a fan capacity of \u003cstrong\u003e600 m³\/h\u003c\/strong\u003e, a \u003cstrong\u003e0.37 kW motor\u003c\/strong\u003e, and a filter area of \u003cstrong\u003e2.8 m²\u003c\/strong\u003e, it captures dust generated during blasting and helps improve visibility inside the cabinet work area.\u003c\/p\u003e\n\u003cp\u003eThe unit uses a filter bag made of \u003cstrong\u003epolyester needle-punched felt\u003c\/strong\u003e. Cleaning is performed manually using an external hand knob: vigorous shaking loosens dust accumulated on the filter bag. Thanks to the \u003cstrong\u003e230 V power connection\u003c\/strong\u003e, the dust collector can be operated without a three-phase power supply.\u003c\/p\u003e\n\u003cp\u003eThe AE-T 0,3 is available in two versions: \u003cstrong\u003ewithout a connection kit\u003c\/strong\u003e or \u003cstrong\u003ewith a complete connection kit\u003c\/strong\u003e for connecting it to the blast cabinet.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eYour Benefits at a Glance\u003c\/h5\u003e\n\u003cp\u003e✅ 600 m³\/h fan capacity\u003cbr\u003e✅ 2.8 m² filter area\u003cbr\u003e✅ Filter bag made of durable polyester needle-punched felt\u003cbr\u003e✅ Manual filter cleaning by shaking via a hand knob\u003cbr\u003e✅ 230 V connection\u003cbr\u003e✅ Compact design\u003cbr\u003e✅ Suitable for blast cabinets with a Ø 100 mm extraction connection\u003cbr\u003e✅ Available with or without a connection kit\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eVariants\u003c\/h5\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;border:1px solid #e6e6e6;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;min-width:1000px;border-collapse:collapse;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#fafafa;\"\u003e\n\u003cth style=\"padding:12px;border-bottom:1px solid #e6e6e6;white-space:nowrap;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"padding:12px;border-bottom:1px solid #e6e6e6;min-width:330px;\"\u003eScope of Delivery\u003c\/th\u003e\n\u003cth style=\"padding:12px;border-bottom:1px solid #e6e6e6;white-space:nowrap;\"\u003eItem Number\u003c\/th\u003e\n\u003cth style=\"padding:12px;border-bottom:1px solid #e6e6e6;min-width:360px;\"\u003eRecommended Use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;white-space:nowrap;\"\u003eWithout connection kit\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eDust collector without connection accessories\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;white-space:nowrap;\"\u003e2133-1000\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eFor existing or custom-designed connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fcfcfc;\"\u003e\n\u003ctd style=\"padding:12px;white-space:nowrap;\"\u003eConnection kit included\u003c\/td\u003e\n\u003ctd style=\"padding:12px;\"\u003eDust collector with hose, clamps, extraction connection, and baffle plate\u003c\/td\u003e\n\u003ctd style=\"padding:12px;white-space:nowrap;\"\u003e2133-1001\u003c\/td\u003e\n\u003ctd style=\"padding:12px;\"\u003eFor complete connection to a suitable blast cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\n\u003cdiv style=\"width:100%;overflow-x:auto;border:1px solid #e6e6e6;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;min-width:720px;border-collapse:collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eW 560 × D 375 × H 1045 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eApprox. 38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eIntake connection\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eØ 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eMotor power\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003e0.37 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003ePower connection\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003ePaint finish\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eRed, standard version; other paint finishes available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eFilter media\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003ePolyester needle-punched felt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eFilter area\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003e2.8 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;font-weight:700;background:#fafafa;\"\u003eFilter cleaning\u003c\/td\u003e\n\u003ctd style=\"padding:12px;border-bottom:1px solid #ededed;\"\u003eManual, by shaking the filter bag using an external hand knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:12px;font-weight:700;background:#fafafa;\"\u003eAir flow rate\u003c\/td\u003e\n\u003ctd style=\"padding:12px;\"\u003e600 m³\/h fan capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch5\u003eScope of Delivery\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eVersion without connection kit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e✔ AE-T 0,3 Blast Cabinet Dust Collector\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVersion with connection kit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e✔ AE-T 0,3 Blast Cabinet Dust Collector\u003cbr\u003e✔ PU extraction hose, Ø 102 mm, 0.4 mm wall thickness, length 2 m\u003cbr\u003e✔ Polyurethane ester casing, reinforced with a steel spiral\u003cbr\u003e✔ 2 screw clamps or hose clamps, Ø 90 to 110 mm\u003cbr\u003e✔ Extraction connection, Ø 100 mm, for blast cabinets, with flange\u003cbr\u003e✔ Baffle plate for blast cabinet\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eManual Filter Cleaning\u003c\/h5\u003e\n\u003cp\u003eDuring operation, dust accumulates on the filter bag. To clean it, the external \u003cstrong\u003ehand knob\u003c\/strong\u003e is operated to shake the filter bag mechanically. This loosens some of the dust adhering to the filter surface.\u003c\/p\u003e\n\u003cp\u003eCleaning should be performed regularly with the fan turned off. How often this is necessary depends, among other things, on the abrasive media, the amount of dust, the duration of use, and the condition of the filter. The filter bag must also be checked regularly and replaced if damaged or if filter performance declines.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eTypical Applications\u003c\/h5\u003e\n\u003cp\u003e✔ Blast cabinets\u003cbr\u003e✔ Glass bead blasting\u003cbr\u003e✔ Corundum blasting\u003cbr\u003e✔ Rust removal and cleaning work\u003cbr\u003e✔ Workshops and metalworking shops\u003cbr\u003e✔ Industrial blasting\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eConnection and Operation\u003c\/h5\u003e\n\u003cp\u003eThe AE-T 0,3 is designed for blast cabinets with a \u003cstrong\u003eØ 100 mm\u003c\/strong\u003e extraction connection. If you choose the version without the connection kit, the necessary connecting parts must already be available or must be purchased separately.\u003c\/p\u003e\n\u003cp\u003eTo ensure trouble-free operation, the extraction hose must be installed so that it is airtight. The specified air flow rate of 600 m³\/h refers to the fan capacity. The actual effective extraction capacity may vary depending on the hose routing, filter condition, and system resistance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch5\u003eFAQ – Frequently Asked Questions\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhat variants are available?\u003c\/strong\u003e\u003cbr\u003eThe AE-T 0,3 is available either without a connection kit or with a complete connection kit included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is included in the version without the connection kit?\u003c\/strong\u003e\u003cbr\u003eThis version includes the AE-T 0,3 blast cabinet dust collector without a hose, hose clamps, extraction connection, or baffle plate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is included in the connection kit?\u003c\/strong\u003e\u003cbr\u003eThe connection kit consists of a 2-meter-long PU extraction hose (Ø 102 mm), two hose clamps (Ø 90 to 110 mm), an extraction connection (Ø 100 mm) with a flange, and a baffle plate for the blast cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do you clean the filter bag?\u003c\/strong\u003e\u003cbr\u003eCleaning is performed manually. A hand knob is used to mechanically shake the filter bag, causing accumulated dust to detach from the filter surface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should the filter cleaning be performed?\u003c\/strong\u003e\u003cbr\u003eCleaning should be performed regularly and with the fan turned off. The required interval depends on the amount of dust, duration of use, and the condition of the filter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor which blast cabinets is the AE-T 0,3 suitable?\u003c\/strong\u003e\u003cbr\u003eThe dust collector is suitable for blast cabinets with a Ø 100 mm extraction connection and a corresponding airflow requirement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of electrical connection does the system require?\u003c\/strong\u003e\u003cbr\u003eThe AE-T 0,3 operates on 230 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of filter media is used?\u003c\/strong\u003e\u003cbr\u003eThe filter bag is made of polyester needle-punched felt.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow large is the filter area?\u003c\/strong\u003e\u003cbr\u003eThe filter area is 2.8 m².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the air flow rate?\u003c\/strong\u003e\u003cbr\u003eThe fan capacity is 600 m³\/h.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the dust collector also be used with third-party blast cabinets?\u003c\/strong\u003e\u003cbr\u003eGenerally speaking, yes, provided that the connection diameter, air requirements, and installation conditions are compatible with the respective cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the paint finish always red?\u003c\/strong\u003e\u003cbr\u003eRed is the standard paint finish. The paint finish may vary depending on the model or production series.\u003c\/p\u003e","brand":"Contracor","offers":[{"title":"without","offer_id":50768451207515,"sku":"2133-1000","price":1130.5,"currency_code":"EUR","in_stock":true},{"title":"including","offer_id":50768451240283,"sku":"2133-1001","price":1261.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/sandstrahlkabinen-absaugung-ae-t-03-radler-und-ruf-2133-1000.jpg?v=1749573341"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/collections\/kategorie-strahlkabinen-absaugung.jpg?v=1774695586","url":"https:\/\/strahltechnik-express.de\/en-it\/collections\/sandstrahlkabinen-absaugung.oembed","provider":"ABS Strahltechnik","version":"1.0","type":"link"}