{"product_id":"clemco-druckprufmanometer-hng-komplettset","title":"HNG nozzle pressure test gauge, Complete Set","description":"\u003ch5\u003eClemco HNG Nozzle Pressure Test Gauge – Test nozzle pressure directly under actual blasting load\u003c\/h5\u003e\u003cp\u003eThe Clemco HNG nozzle pressure test gauge is a diagnostic tool for abrasive blasting systems. It allows the actual blasting pressure available at the nozzle to be measured during operation. This value takes into account pressure losses caused by compressed-air treatment, fittings, couplings, and the blast hose.\u003c\/p\u003e\u003cdiv style=\"background:#f5f5f5;padding:16px;border-radius:10px;margin:16px 0;\"\u003e\n\u003cstrong\u003eYour Benefits\u003c\/strong\u003e\u003cbr\u003e✅ Measurement close to the blast nozzle\u003cbr\u003e✅ Diagnosis of pressure losses under load\u003cbr\u003e✅ Helps with compressor and hose sizing\u003cbr\u003e✅ Supports reproducible blasting results\u003cbr\u003e✅ Complete kit for maintenance and service\u003c\/div\u003e\u003chr\u003e\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\u003cdiv style=\"overflow-x:auto;margin:16px 0;border:1px solid #d9dee3;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;border-collapse:separate;border-spacing:0;min-width:620px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"width:36%;padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#eef1f3;font-weight:700;\"\u003eModel\u003c\/td\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;\"\u003eHNG\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;font-weight:700;\"\u003eProduct type\u003c\/td\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;\"\u003eNozzle pressure test gauge \/ pressure test gauge\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#eef1f3;font-weight:700;\"\u003eItem No.\u003c\/td\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;\"\u003e01232I\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;font-weight:700;\"\u003eMeasurement\u003c\/td\u003e\u003ctd style=\"padding:11px 12px;border-bottom:1px solid #e1e5e8;background:#f8f9fa;\"\u003eOperating pressure in the blast hose near the nozzle\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"padding:11px 12px;background:#eef1f3;font-weight:700;\"\u003eSupply format\u003c\/td\u003e\u003ctd style=\"padding:11px 12px;\"\u003eComplete set\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003chr\u003e\u003ch5\u003eWhy Nozzle Pressure Is Critical\u003c\/h5\u003e\u003cp\u003eA high outlet pressure at the compressor does not automatically mean that the same pressure is available at the nozzle. Undersized piping, long hoses, restrictive couplings, contaminated filters, or a worn nozzle can cause significant pressure losses.\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eTypical Applications\u003c\/h5\u003e\u003cp\u003e✔ Troubleshooting low blasting performance\u003cbr\u003e✔ Comparing different hose lengths and diameters\u003cbr\u003e✔ Testing after maintenance or modifications\u003cbr\u003e✔ Documenting recurring system conditions\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eMeasurement and Safety\u003c\/h5\u003e\u003cp\u003eMeasurements should only be performed by trained personnel in accordance with the application instructions. Wear personal protective equipment and keep hands out of the direct blast and rebound areas.\u003c\/p\u003e\u003cp\u003e💡 \u003cstrong\u003ePractical tip:\u003c\/strong\u003e Document a reference value after successful commissioning. This makes later deviations easier to identify and diagnose.\u003c\/p\u003e\u003chr\u003e\u003ch5\u003eFAQ\u003c\/h5\u003e\u003cp\u003e\u003cstrong\u003eWhy is the blast pot pressure gauge not sufficient?\u003c\/strong\u003e\u003cbr\u003eIt does not show the pressure losses between the blast pot and the nozzle.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen should measurements be taken?\u003c\/strong\u003e\u003cbr\u003eIn case of performance problems, after modifications, when using a new nozzle size, and as part of preventive maintenance.\u003c\/p\u003e","brand":"Clemco","offers":[{"title":"Default Title","offer_id":52744693809499,"sku":"01232I","price":56.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/druckpruef-manometer-hng-clemco-01232i.jpg?v=1775217222","url":"https:\/\/strahltechnik-express.de\/en-es\/products\/clemco-druckprufmanometer-hng-komplettset","provider":"ABS Strahltechnik","version":"1.0","type":"link"}